System modules, Input frequency = 200 khz – Lenze ECSCAxxx User Manual
Page 334
System modules
DFIN_IO_DigitalFrequency (node number 21)
Inputs_DFIN
l
334
EDBCSXA064 EN 3.2
13.16.1.1
Configuration master frequency input signal
You configure the type of the master frequency input signal via C0427:
C0427 = 0 (2 phases)
Track
CW rotation
CCW rotation
B
B
A
A
Z
Z
A
Track A leads by 90°
(DFIN_nIn_v = positive
value)
Track A lags by 90°
(DFIN_nIn_v = negative
value)
B
˘
˘
Signal sequence with phase shift (CW
rotation)
C0427 = 1 (A = speed / B = direction)
Track
CW rotation
CCW rotation
B
B
A
A
Z
Z
A
Transmits the speed.
Transmits the speed
B
= FALSE
(DFIN_nIn_v = positive
value)
= TRUE
(DFIN_nIn_v = negative
value)
Control of the direction of rotation via
track B
C0427 = 2 (A or B = speed or direction)
Track
CW rotation
CCW rotation
B
B
A
A
Z
Z
A
Transmits speed and
direction of rotation
(DFIN_nIn_v = positive
value)
= FALSE
B
= FALSE
Transmits speed and
direction of rotation
(DFIN_nIn_v = negative
value)
Control of speed and direction of
rotation via track A or track B
Transfer function
DFIN_nIn_v
+ f [Hz] @
60
Number of incr. from C0420
@ 2
14
15000
Example:
ƒ
Input frequency = 200 kHz
ƒ
C0420 = 2048
DFIN_nIn_v [rpm]
+ 200000 Hz @ 60
2048 +