System modules – Lenze ECSCAxxx User Manual
Page 333
System modules
DFIN_IO_DigitalFrequency (node number 21)
Inputs_DFIN
l
333
EDBCSXA064 EN 3.2
IMPORTANT
Possible settings
Code
Selection
Lenze/
{Appl.}
Designation
No.
[C0421] Encoder volt
0
Encoder voltage
^ 331
^ 115
^ 122
0
5.0 V
Sets C0419 = 0 ("common") if the
value is altered.
1
5.6 V
2
6.3 V
3
6.9 V
4
7.5 V
5
8.1 V
C0426 DIS: In
Signal at DFIN input
Only display
^ 331
−32767
{1 rpm}
32767
[C0427] Enc. signal
0
Function of the master frequency
input signals on X8 (DFIN)
^ 331
^ 115
^ 122
0
2−phase
1
A: speed
B: direction
2
A or B: speed or direction
C0428 DFIN TP sel.
0
DFIN touch probe signal source
^ 336
^ 331
0
Zero pulse of position encoder (C0490) X7/X8
1
Touch probe input TP1
X6/DI1
2
Zero pulse of digital frequency input
X8
C0429 TP1 delay
0
DFIN dead time compensation
TP1 (DI1)
^ 336
^ 331
−32767
{1 inc}
32767
C0431 DFIN TP Edge
0
DFIN touch probe TP1 edge
(for touch probe via digital input
X6/DI1 (C0428 = 1))
^ 336
0
Rising edge TP1
1
Falling edge TP1
2
Rising and falling edge TP1
3
Switched off
[C0491] X8 in/out
0
Function of X8
^ 331
^ 115
^ 122
0
X8 is input
1
X8 is output