6 can_management (node number 101), System modules – Lenze ECSCAxxx User Manual
Page 277
System modules
CAN_Management (node number 101)
l
277
EDBCSXA064 EN 3.2
13.6
CAN_Management (node number 101)
This SB
ƒ
serves to activate a reset node to e.g. accept changes in the transfer rate and
addressing.
ƒ
serves to process statuses as Communication Error, Bus Off State, etc. in the PLC
program.
ƒ
the instant of transmission of CAN2_Out and CAN3_Out can be influenced.
ƒ
serves to monitor the system bus communication.
)
Note!
ƒ
The process image for this SB is created in the course of a fixed system task
(interval: 1 ms).
ƒ
Even if this SB has not been assigned to the control configuration, a reset
node can be carried out via C0358.
CAN_bResetNode_b
CAN_Management
C0358
CAN2_OUT
CAN_bCe2CommErrCanIn2_b
CAN_ResetNode
CAN_bTxCan2Synchronized_b
CAN1_IN communication error
CAN2_IN communication error
CAN3_IN communication error
CAN bus off state
CAN_bCe1CommErrCanIn1_b
CAN_bCe3CommErrCanIn3_b
CAN_bCe4BusOffState_b
CAN_SYNC
CAN_bTxCan3Synchronized_b
1
CAN_bFreePdoTxBufferOverflow_b
CAN_bFreePdoRxOverflow_b
CAN_bOverrunLifeTime_b
CAN_byNodeAddress
CAN_byState
CAN state (C0359)
CAN node address (C0350)
Free Pdo Tx buffer overflow
Free Pdo Rx overflow
Overrun life time
CAN3_OUT
CAN_SYNC
Fig. 13−10
System block "CAN_Management"
I
Tip!
More detailed information on the CAN bus can be found in the appendix of
this documentation (
¶ 440).