System modules – Lenze ECSCAxxx User Manual
Page 276

System modules
ANALOG1_IO (node number 11)
Inputs_ANALOG1 (analog input)
l
276
EDBCSXA064 EN 3.2
System variables
Variable
Data
type
Signal
type
Address
Display
code
Display
format
Comments
AIN1_nIn_a
integer
analog
%IW11.0
C0400
dec [%]
Analog input 1
AIN1_bError_b
BOOL
binary
%IX11.1.0
˘
˘
Only when C0034 = 1:
TRUE, if
½I½ < 2 mA
Codes
Code
Possible settings
IMPORTANT
No.
Designation
Lenze/
{Appl.}
Selection
C0026
Offset for relative analog signals
(AIN)
^ 275
^ 347
1 FCODE(offset)
0,0
−199,99
{0.01 %}
199,99 FCODE_nC26_1_a
2 FCODE(offset)
0,0
FCODE_nC26_2_a
C0027
Gain for relative analog signals
(AIN)
^ 275
^ 347
1 FCODE(gain)
100,0
−199,99
{0.01 %}
199,99 FCODE_nC27_1_a
2 FCODE(gain)
100,0
FCODE_nC27_2_a
C0034 Mst current
0
Master voltage/master current
on analog input (AIN1_nIn_a)
^ 275
0
−10 ... + 10 V
Master voltage
1
+4 ... +20 mA
Master current
2
−20 ... +20 mA
C0400 DIS: AnalogIn
Signal at the analog input
Read only
−199.99
{0.01 %}
199.99
C0598 MONIT SD5
3
Fault response − master current
monitoring at X6 < 2 mA
"MastISourceDef"
^ 275
0
TRIP
2
Warning
3
Off