1 inputs_can2, Inputs_can2, System modules – Lenze ECSCAxxx User Manual
Page 292
System modules
CAN2_IO (node number 32)
Inputs_CAN2
l
292
EDBCSXA064 EN 3.2
13.9.1
Inputs_CAN2
System variables
Variable
Data
type
Signal
type
Address
Display
code
Display
format
Comments
CAN2_nInW1_a
integer
analog
%IW32.0
C0866/4
dec [%]
CAN2_nInW2_a
%IW32.1
C0866/5
CAN2_bInB0_b
BOOL
binary
%IX32.0.0
hex
...
...
C0863/3
CAN2_bInB15_b
%IX32.0.0
CAN2_bInB16_b
%IX32.1.0
...
...
C0863/4
CAN2_bInB31_b
%IX32.1.15
CAN2_dnInD1_p
double
integer
position
%ID32.0
C0867/2
dec [inc]
CAN2_nInW3_a
integer
analog
%IW32.2
C0866/6
dec [%]
CAN2_nInW4_a
%IW32.3
C0866/7
User data
The first 4 bytes from the 8 bytes of received user data are assigned to several variables of
different data types. According to requirements, they thus can be evaluated by the PLC
program as:
ƒ
binary information (1 bit)
ƒ
quasi−analog value (16 bit)
ƒ
angle information (32 bit)
Byte
Variable (1 bit)
Variable (16 bit)
Variable (32 bit)
1, 2
CAN2_bInB0_b
...
CAN2_bInB15_b
CAN2_nInW1_a
CAN2_dnInD1_p
3, 4
CAN2_bInB16_b
...
CAN2_bInB31_b
CAN2_nInW2_a
5, 6
CAN2_nInW3_a
7, 8
CAN2_nInW4_a