Commissioning – Lenze ECSCAxxx User Manual
Page 133
Commissioning
Operation with motors from other manufacturers
Entering motor data manually
l
133
EDBCSXA064 EN 3.2
IMPORTANT
Possible settings
Code
Selection
Lenze/
{Appl.}
Designation
No.
C0058 Rotor diff
−90.0
Rotor displacement angle (offset
angle)
Input in case of Lenze motor with
l
resolver: −90°
l
hiperface absolute value
encoder: 0°
Code value is adapted by the
rotor position adjustment
function (C0095).
Only relevant for the operation
of synchronous motors.
^ 138
−180.0
{0.1
_}
179.9
[C0080] Res pole no.
1
Number of pole pairs of resolver
1
{1}
10
[C0081] Mot power
3.20
Rated motor power according to
nameplate
0.01
{0.01 kW}
500.00
[C0084] Mot Rs
1.10
Stator resistance of the motor
The upper limit is
device−dependent.
0.00
{0.01
W}
95.44 ECSxS/P/M/A004
47.72 ECSxS/P/M/A008
23.86 ECSxS/P/M/A016
11.93 ECSxS/P/M/A032
7.95 ECSxS/P/M/A048
5.96 ECSxS/P/M/A064
[C0085] Mot Ls
5.30
Leakage inductance of the motor
0.00
{0.01 mH}
200.00
[C0087] Mot speed
3700
Rated motor speed
300
{1 rpm}
16000
[C0088] Mot current
7.0
Rated motor current
0.5
{0.1 A}
500.0
[C0089] Mot
frequency
185
Rated motor frequency
10
{1 Hz}
1000
[C0090] Mot voltage
325
Rated motor voltage
50
{1 V}
500
[C0091] Mot cos phi
1.0
cos
j of the asynchronous motor
0.50
{0.01}
1.00
[C0095] Rotor pos adj
0
Activation of rotor position
adjustment for automatic
determination of the rotor
displacement angle.
C0058 displays the determined
rotor displacement angle (offset
angle).
^ 138
0
Inactive
1
Active
C0110 Service Code
Fine adjustment − mutual
inductance
50
{1 %}
200