Appendix – Lenze ECSCAxxx User Manual
Page 390
Appendix
Code table
l
390
EDBCSXA064 EN 3.2
IMPORTANT
Possible settings
Code
Selection
Lenze/
{Appl.}
Designation
No.
C0093 Drive ident
Device identification of the ECS
axis module
Read only
0
Defective power section
1
No power section recognised
4
ECSxS/P/M/A004C4
8
ECSxS/P/M/A008C4
16
ECSxS/P/M/A016C4
32
ECSxS/P/M/A032C4
48
ECSxS/P/M/A048C4
64
ECSxS/P/M/A064C4
65
ECSxS/P/M/A064C2
C0094 Password
0
Keypad password
Parameter access protection for
the keypad
0
{1}
9999 When the password is activated,
only the codes of the user menu
(C0517) can be accessed. Further
possible selections: see C0096
0 = no password
[C0095] Rotor pos adj
0
Activation of rotor position
adjustment for automatic
determination of the rotor
displacement angle.
C0058 displays the determined
rotor displacement angle (offset
angle).
^ 138
0
Inactive
1
Active
C0096
Extended password protection
for bus systems with activated
password (C0094)
All codes in the user menu can be
accessed.
1 AIF/CAN prot.
0
No access protection
AIF access protection
2 AIF/CAN prot.
0
No access protection
CAN access protection
0
No access protection
Full access
1
Read protection
Reading not possible
2
Write protection
Writing not possible
3
Read/write protection
Reading and writing not possible
C0097 DIS:Lt−Ident
0
Power stage identification
0
{1}
255
C0098 Set position
0
Home position of encoder
−2147483647
{1 inc}
2147483647
C0099 S/W version
Firmware version
Read only
0,0
{0,1}
25,5
C0105 QSP Tif
0.0
Deceleration time for quick stop
(QSP)
^ 324
^ 361
0.000
{0.001 s}
999.999 Relating to speed variation n
max
(C0011) ...0 rev./min.