Appendix – Lenze ECSCAxxx User Manual
Page 425
Appendix
Code table
l
425
EDBCSXA064 EN 3.2
IMPORTANT
Possible settings
Code
Selection
Lenze/
{Appl.}
Designation
No.
C2453
Source for system bus node
addresses of
CANaux_IN/CANaux_OUT (CAN
bus interface X14)
^ 160
1 CANa addr sel
0
CAN node address (C2450)
Address CANaux1_IN/OUT
2 CANa addr sel
0
CAN node address (C2450)
Address CANaux2_IN/OUT
3 CANa addr sel
0
CAN node address (C2450)
Address CANaux3_IN/OUT
0
C2450 (auto)
Automatically determined by
C2450
1
C2454 (man.)
Determined by C2454
C2454
Alternative node addresses for
CANaux_IN/CANaux_OUT (CAN
bus interface X14)
^ 160
1 CANa addr.
129
1
{1}
512 CANaux1_INaddress 2
2 CANa addr.
1
CANaux1_OUTaddress 2
3 CANa addr.
257
CANaux2_INaddress 2
4 CANa addr.
258
CANaux2_OUTaddress 2
5 CANa addr.
385
CANaux3_IN address 2
6 CANa addr.
386
CANaux3_OUT address 2
C2455
Identifier for
CANaux_IN/CANaux_OUT (CAN
bus interface X14)
Read only
^ 458
1 CANa Id
1
{1}
2047 Identifier CANaux1_IN
2 CANa Id
Identifier CANaux1_OUT
3 CANa Id
Identifier CANaux2_IN
4 CANa Id
Identifier CANaux2_OUT
5 CANa Id
Identifier CANaux3_IN
6 CANa Id
Identifier CANaux3_OUT
C2456
CAN time settings for CAN bus
interface X14 (CAN−AUX)
^ 163
1 CANa times
3000
0
{1 ms}
65000 CAN−AUX boot−up time:
Delay time after mains
connection for initialisation
through the master.
2 CANa times
0
CANaux2...3_OUT cycle times:
Factor for the task time to send
process data telegram.
0 = event−controlled
transmission
3 CANa times
0
4 CANa times
20
Delay time for initial
transmission of the process data
objects 2 and 3 after the CAN bus
changed to "Operational"
C2457
Monitoring time for
CANaux1...3_IN (CAN bus
interface X14)
^ 202
1 CE monit time
3000
1
{1 ms}
65000 CE11 monitoring time
2 CE monit time
3000
CE12 monitoring time
3 CE monit time
3000
CE13 monitoring time