Commissioning – Lenze ECSCAxxx User Manual
Page 120
Commissioning
Setting of the feedback system for position and speed control
TTL/SinCos encoder as position encoder and resolver as speed encoder
l
120
EDBCSXA064 EN 3.2
IMPORTANT
Possible settings
Code
Selection
Lenze/
{Appl.}
Designation
No.
C0414 DIS: ResQual.
Resolver modulation
Quality of the resolver excitation
amplitude set under C0416
(recommendation: 0.5 ... 1.2;
ideal 1.0)
^ 113
0.00
{0.01}
1,60
[C0416] Resolver adj.
5
Resolver excitation amplitude
^ 113
0
100 %
1
80 %
2
68 %
3
58 %
4
50 %
5
45 %
6
40 %
7
37 %
[C0417] Resolver cor.
0
Resolver adjustment
^ 147
0
Ready
1
Start adjustment
2
Loading default values
[C0419] Enc. setup
110
Encoder selection
l
Selection of encoder type
indicated on the nameplate of
the Lenze motor.
l
The encoder data (C0420,
C0421, C0427) is set
automatically in accordance
with the selection.
^ 331
^ 115
^ 122
0
Common
110
IT512−5V
Incremental encoder with TTL
level
111
IT1024−5V
112
IT2048−5V
113
IT4096−5V
210
IS512−5V
SinCos encoder
211
IS1024−5V
212
IS2048−5V
213
IS4096−5V
307
AS64−8V
SinCos absolute value encoder
with Hiperface® interface
(single−turn)
Selections 307, 308, 309 are only
possible with operating system
7.0 or higher.
308
AS128−8V
309
AS256−8V
310
AS512−8V
311
AS1024−8V
407
AM64−8V
SinCos absolute value encoder
with Hiperface® interface
(multi−turn)
Selections 407, 408, 409 are only
possible with operating system
7.0 or higher.
408
AM128−8V
409
AM256−8V
410
AM512−8V
411
AM1024−8V