System modules – Lenze ECSCAxxx User Manual
Page 315
System modules
CANaux3_IO (node number 36)
l
315
EDBCSXA064 EN 3.2
Codes
Code
Possible settings
IMPORTANT
No.
Designation
Lenze/
{Appl.}
Selection
C2456
CAN time settings for CAN bus
interface X14 (CAN−AUX)
^ 163
1 CANa times
3000
0
{1 ms}
65000 CAN−AUX boot−up time:
Delay time after mains
connection for initialisation
through the master.
2 CANa times
0
CANaux2...3_OUT cycle times:
Factor for the task time to send
process data telegram.
0 = event−controlled
transmission
3 CANa times
0
4 CANa times
20
Delay time for initial
transmission of the process data
objects 2 and 3 after the CAN bus
changed to "Operational"
C2457
Monitoring time for
CANaux1...3_IN (CAN bus
interface X14)
^ 202
1 CE monit time
3000
1
{1 ms}
65000 CE11 monitoring time
2 CE monit time
3000
CE12 monitoring time
3 CE monit time
3000
CE13 monitoring time
C2491
Process data input words
(hexadecimal) for CAN bus
interface X14
Hexadecimal value is bit−coded.
Read only
1 CANa IN bits
0
{1 hex}
FFFF CANaux1_IN (bit 0 ... 15)
2 CANa IN bits
CANaux1_IN (bit 16 ... 31)
3 CANa IN bits
CANaux2_IN (bit 0 ... 15)
4 CANa IN bits
CANaux2_IN (bit 16 ... 31)
5 CANa IN bits
CANaux3_IN (bit 0 ... 15)
6 CANa IN bits
CANaux3_IN (bit 16 ... 31)