System modules

AIF2_IO_AutomationInterface (node number 42)
Outputs_AIF2

13

l

270

EDBCSXA064 EN 3.2

User data

The first 4 bytes of the 8 bytes user data to be sent can be written via several variables of
different data types. According to requirements, data can therefore be transferred from
the PLC program as

ƒ

binary information (1 bit)

ƒ

status word/quasi−analog value (16 bit)

ƒ

angle information (32 bit)

)

Note!

Avoid simultaneous overwriting via different variable types to ensure data
consistency.
Thus, bytes 1 and 2 should only be overwritten by

ƒ

variable AIF2_dnOutD1_p,

ƒ

variable AIF2_nOutW1_a or

ƒ

variables AIF2_bFDO0_b ... AIF2_bFDO15_b.

Byte

Variable (1 bit)

Variable (16 bit)

Variable (32 bit)

1, 2

AIF2_bFDO0_b

...

AIF2_bFDO15_b

AIF2_nOutW1_a

AIF2_dnOutD1_p

3, 4

AIF2_bFDO16_b

...

AIF2_bFDO31_b

AIF2_nOutW2_a

5, 6

AIF2_nOutW3_a

7, 8

AIF2_nOutW4_a