Commissioning – Lenze ECSCAxxx User Manual
Page 121
Commissioning
Setting of the feedback system for position and speed control
TTL/SinCos encoder as position encoder and resolver as speed encoder
l
121
EDBCSXA064 EN 3.2
IMPORTANT
Possible settings
Code
Selection
Lenze/
{Appl.}
Designation
No.
[C0420] Encoder const.
512
Number of increments of the
encoder
^ 331
^ 115
^ 122
1
{1 inc/rev}
8192 Sets C0419 = 0 ("common") if the
value is altered.
[C0421] Encoder volt
0
Encoder voltage
^ 331
^ 115
^ 122
0
5.0 V
Sets C0419 = 0 ("common") if the
value is altered.
1
5.6 V
2
6.3 V
3
6.9 V
4
7.5 V
5
8.1 V
[C0427] Enc. signal
0
Function of the master frequency
input signals on X8 (DFIN)
^ 331
^ 115
^ 122
0
2−phase
1
A: speed
B: direction
2
A or B: speed or direction
[C0491] X8 in/out
0
Function of X8
^ 331
^ 115
^ 122
0
X8 is input
1
X8 is output