beautypg.com

Set gvrp timer – Allied Telesis AT-S100 User Manual

Page 217

background image

AT-S100 Management Software User’s Guide

Section II: Advanced Configuration

217

SET GVRP TIMER

Syntax

set gvrp timer join|leave|leaveall <1-65535> ge<1-28>

Parameters

default

Returns the GARP timers to their default settings.

join

Specifies the Join timer for joining the group. Enter a

value in centiseconds, which are one hundredths of a
second. The default is 20 centiseconds.

leave

Specifies the Leave timer for leaving a group. Enter a

value in centiseconds, which are one hundredths of a
second. The default is 60 centiseconds.

leaveall

Specifies the LeaveAll timer for leaving all groups.

Enter a value in centiseconds, which are one
hundredths of a second. The default is 1,000
centiseconds.

<1-65535>

Specifies the timer value in hundredths of a second.

Enter a value between 1 and 65,535.

ge<1-28>

Specifies a port. There are 28 ports on the 9000/28
switch. To specify a port, precede the port number
with “ge.”

Description

Use the SET GVRP TIMER command to set the GARP timers to join or
leave a group.

Note

You must make the settings for these timers the same on all GVRP-
active network devices.

Examples

The following command sets the Join timer to 0.1 second for all GVRP
applications on port 8:

switch#configure terminal

switch(config)#set gvrp timer join 10 ge8