beautypg.com

Clock summer-time recurring – Allied Telesis AT-S100 User Manual

Page 117

background image

AT-S100 Management Software User’s Guide

Section I: Command Modes

117

CLOCK SUMMER-TIME RECURRING

Syntax

clock summer-time ZONENAME recurring START-WEEK START-
DAY START-MONTH START-TIME END-WEEK END-DAY END-MONTH
END-TIME <1-180>

no clock summer-time

Parameters

ZONENAME

Describes the summertime zone, up to 6 characters

long.

recurring

Specifies that this summertime setting applies every

year from now on.

START-WEEK

Indicates the week of the month when summertime
starts in the range of 1 to 5. The value of 5 indicates
the last week that has specified day in it for the
specified month. For example, to start summertime
on the last Sunday of the month, enter 5 for START-
WEEK and “sun” for START-DAY.

START-DAY

Indicates the day of the week when summertime

starts. Use the first three letters of each day of the
week. Valid values are “mon,” “tue,” “wed,” “thu,” “fri,”
“sat,” and “sun.”

START-MONTH

Specifies the month that summer time starts. Use the

first three letters of each month to indicate the name
of a month. Valid values are “jan, “feb,” “mar,” “apr,”
“may,” “jun,” “apr,” “may,” “jun,” “jul,” “aug,” “sep,”
“oct,” “nov,” and “dec.”

START-TIME

Indicates the time of day that summer time starts in
24-hour format: HH:MM where H represents hours
and M represents minutes.

END-WEEK

Indicates the week of the month when summer time

ends in the range of 1 through 5. The value of 5
indicates the last week of the month.

END-DAY

Specifies the day of the week when summer time
ends. Use the first three letters of each day of the
week. Valid values are “mon,” “tue,” “wed,” “thu,” “fri,”
“sat,” and “sun.”