HP StorageWorks 2.32 Edge Switch User Manual
Page 91
Edge Switch Element Manager user guide
91
Configure Ports Procedure (Open Systems Management Style)
NOTE:
This procedure applies only to the Edge Switch 2/32. Open Systems Management Style
(OSMS) is not available on the Edge Switch 2/24.
To configure Edge Switch 2/32 ports in Open Systems management style, use the following steps:
1.
Select Configure > Ports. The Configure Ports dialog box appears.
Figure 29
Configure Ports dialog box (Open Systems Management Style)
Ports are numbered from 0 through 31.
2.
Click a Name box and type a name that reflects the end device connected through the port.
For example, use
XYZ
server. The
XYZ
is the brand name of the server.
3.
Block or unblock operation for a port by clicking the check box in the Blocked column. When
a check mark displays, the port is blocked.
4.
Enable or disable extended distance buffering for the port by clicking the check box in the
10-100 km column. When a check mark displays, extended distance buffering is enabled.