Class 3 statistics, Error statistics – HP StorageWorks 2.32 Edge Switch User Manual
Page 68
Monitoring and managing the switch
68
•
Busied Frames—The number of F_BSY frames generated by this F_Port against Class 2
frames. This can occur if frames are received before the switch completes initialization or if the
switch is servicing so many requests that it can not process a new request. The port generates
frames if the switch is not ready to accept commands. This may indicate temporary congestion.
•
Rejected Frames—The number of F_RJT frames generated by this F_Port against Class 2
frames.
These frames usually occur because of attached device errors. The device is expected to correct
the error based on the reject code, then retry its request. If the device is able to recover, there is
no cause for concern. If not, further troubleshooting may be necessary. There are no thresholds
for this value. Typically, this occurs because the destination is not available due to the device’s
action.
•
Four-Byte Words Rx—The number of four-byte words received.
•
Four-Byte Words Tx—The number of four-byte words transmitted.
Class 3 Statistics
The Class 3 Statistics table includes:
•
Received Frames—The number of Class 3 frames received by this port from its attached
port.
•
Transmitted Frames—The number of Class 3 frames transmitted by this port to its attached
port.
•
Discarded Frames—The number of Class 3 frames discarded, including multicast frames
with bad destination identifiers (D_IDs).
The switch increments this count when it discards a frame that cannot be routed. This occurs
most frequently when a destination becomes unavailable without the source realizing that the
destination is unavailable. There are no thresholds for this value. Typically, this occurs when the
destination is not available due to the destination device’s action.
•
Four Byte Words Rx—The number of four-byte words received.
•
Four Byte Words Tx—The number of four-byte words transmitted.
Error statistics
Port errors indicate that a port is not operating correctly. Use this data to isolate problems with port
and link operations. The statistics in this table include:
•
Link failures—A link failure was recorded in response to a not operational sequence (NOS),
protocol timeout, or port failure. At the Hardware View, a yellow triangle displays to indicate a
link incident, or a blinking red and yellow diamond displays to indicate a port failure.
•
Sync losses—A loss of synchronization was detected because the attached device was reset
or disconnected from the port. At the Hardware View, a yellow triangle displays to indicate a
link incident.
•
Signal losses—A loss of signal was detected because the attached device was reset or
disconnected from the port. At the Hardware View, a yellow triangle displays to indicate a link
incident.