• Activate—Click this button to activate settings in this dialog box.
Warning and error messages display under the following circumstances:
• If one or more of the nodes logged into a port does not match the WWN or nickname
configured in the field by the WWN option button, a warning dialog box appears after
you activate the configuration. This warning box displays a list of all nodes that will be
logged off if you continue. If you click Continue on the warning box, these nodes will
be logged off and the port will only attach to the device with the WWN or nickname
configured in the
WWN field.
• An error message displays after you activate the configuration if the format for the
WWN entered in the WWN field is not valid (not in
xx.xx.xx.xx.xx.xx.xx.xx
format) or if you have entered a nickname that was not configured through the Element
Manager.
•
Clear Threshold Alert(s)—Click this option to display the Clear Threshold Alert(s) dialog
box. Click the appropriate option to clear alerts for the selected port only or for all ports on the
switch. This clears all attention indicators that notify users of threshold alerts in dialog boxes
and views. This action also restarts the notification interval and the cumulative minutes for
utilization % interval.
Figure 18
Clear Threshold Alert(s) dialog box