HP StorageWorks 2.32 Edge Switch User Manual
Page 53
Edge Switch Element Manager user guide
53
•
07 Non-HP switch at other end of the ISL
—The cable is connected to a non-HP
switch, and interop mode is set to Open Fabric 1.0 mode.
•
08 ISL connection not allowed on this port
—The port type configuration
does not match the actual port use. (The port is configured as an F_Port, but attaches to a
switch or director.)
•
10 Port binding violation - Unauthorized WWN
—The WWN entered to
configure Port Binding for this port is not valid, or a nickname was used that is not
configured for the attached device in the Element Manager.
•
11 Unresponsive node connected to port
—Possible causes are:
• Hardware problem on switch or on a connected node where ELP frames are not
delivered, the response is not received, or a fabric login (FLOGI) cannot be received.
There may be problems in the switch SBAR.
• Faulty or dirty cable connection.
• Faulty host bus adapters that do not send out FLOGI within a reasonable time frame.
•
0x0C ESA Security Mismatch
—Processing of Exchange Security Attribute Frame
detected required security feature mismatch.
•
0x0D Fabric Binding Mismatch
—Fabric Binding is enabled and detected a switch
connection with an incompatible fabric membership list. Could also be the result of
problems delivering EFMD ILS.
•
0x0E Authorization Failure Reject
—The switch on the other side of the ISL
detected a security violation. This switch receives notification via a generic reject reason
code and sets its port to the invalid attachment state in sympathy.
•
0x0F Unauthorized Switch Binding WWN
—A Switch Binding error was detected on
either an E_Port or F_Port.
•
0x10 Authentication Failure.
ISL Authentication Check (CHAP) failed—If you wish
to allow the connection, update the authentication lists or disable authentication.
•
0x11 Fabric Mode Mismatch
—A connection was not allowed because:
• An HP M-Series switch or director attempted to connect to an HP switch or director
running in Open Fabric mode.
• An HP M-Series switch or director running in Open Fabric mode attempted to connect to
another vendor’s switch or director with an incorrect ELP revision level.
•
0x12 CNT WAN Extension Mode Mismatch
—The ELP maximum frame sizes were
incompatible because one product running in CNT WAN extension mode attempted to
connect to another product running in a normal mode.
Segmented E_Port messages:
•
Incompatible operating parameters, such as resource allocation
time-out values (R_A_TOV) or error-detect time-out values
(E_D_TOV) are inconsistent
—See ”
Configuring operating parameters
for more information.
•
Duplicate domain IDs
—See ”
Configuring operating parameters
information.