47 new threshold alerts dialog box - second screen – HP StorageWorks 2.32 Edge Switch User Manual
Page 111
Edge Switch Element Manager user guide 111
4.
Click one of the following on the drop-down list in the Name box:
• Transmit. An alert will occur if the threshold set for transmit throughput is reached.
• Receive. An alert will occur if the threshold set for receive throughput is reached.
• Receive and Transmit. An alert will occur if the threshold set for either receive or
transmit throughput is reached.
5.
Click Next. A new screen displays with additional parameters, as shown in
page 111. The name configured for the alert displays at the top of the screen.
(Click Previous to return to the previous screen.)
Figure 47
New Threshold Alerts dialog box - second screen
6.
Enter a percentage from 1 through 100 for % utilization. When throughput reaches this
percentage of port capacity, a threshold alert will occur.
7.
Enter the amount of cumulative minutes in which the % utilization should exist during the
notification interval before an alert is generated. You can also click At any time if you want
an alert to occur whenever the set % utilization is reached. The valid range is 1 to the
8.
Enter the interval in minutes in which throughput is measured and threshold notifications can
occur. The valid range is 5 minutes to 70,560 minutes.