beautypg.com

HP StorageWorks 2.32 Edge Switch User Manual

Page 189

background image

Edge Switch Element Manager user guide 189

Nonredundant director must be
offline to install firmware.

For directors, if the director has only
one CTP card, the director must be set
offline to install a firmware version.

For switches, since the switch has only
a single CTP card, it must be offline to
initiate a firmware installation. Note
that the CTP card is an internal
component and not a FRU.

Set the director or switch offline and install
the firmware.

Not all of the optical transceivers
are installed for this range of ports.

Some ports in the specified range do
not have optical transceivers installed.

Use a port range that is valid for the ports
installed.

Open Trunking is not installed for
this product. Please contact your
sales representative.

The Open Trunking feature key has
not been enabled. This message only
appears if the optional Open
Trunking feature is installed.

Enter the feature key into the Configure
Feature Key dialog box and enable the
key. If you require a feature key, see your
account representative.

Performing this operation will
change the current state to Offline.

This message requests confirmation to
set the director offline.

Click OK to set the director offline or click
Cancel to cancel the operation.

Performing this operation will
change the current state to Online.

This message requests confirmation to
set the director online.

Click OK to set the director online or click
Cancel to cancel the operation.

Performing this action will
overwrite the date/time on the
switch.

Warning that occurs when
configuring the date and time through
the Configure Date and Time dialog
box, that the new time or date will
overwrite the existing time or date set
for the director or switch.

Verify that you want to overwrite the
current date or time.

Periodic Date/Time
synchronization must be cleared.

Action cannot be performed because
Periodic Date/Time Synchronization
option is active.

Click Periodic Date/Time Synchronization
check box in Configure Date and Time
dialog box (Configure menu) to clear
check mark and disable periodic
date/time synchronization.

Port binding was removed from
attached devices that are also
participating in Switch Binding.

Informational message. You removed
Port Binding from attached devices,
but one or more of these devices is
still controlled by Fabric Binding.

Review the Switch Binding Membership
List to determine if the devices should be
members.

Port cannot swap to itself.

Port addresses entered in the Swap
Ports dialog box are the same.

Ensure that address in the first and second
Port Address fields are different.

Port diagnostics cannot be
performed on an inactive port.

This appears when port diagnostics is
run on a port in an inactive state.

Run the diagnostics on an active port.

Table 8

Element Manager messages (continued)

Message

Description

Action

This manual is related to the following products: