Information and error messages

178

Cannot enable Open Trunking
while Enterprise Fabric Mode is
active and the switch is offline.

Enterprise Fabric mode is active and
the switch or director is online and
you attempted to enable Open
Trunking. This message only appears
if the optional Open Trunking feature
is installed.

Perform either of the following steps:

Disable Enterprise Fabric Mode option by
selecting the appropriate fabric in the
Fabric Tree portion of the HAFM Manager
window (Fabrics tab) and then selecting
Enterprise Fabric Mode from the Fabrics
menu. When the Enterprise Fabric Mode
dialog box appears, click Start and follow
prompts to disable the feature.

Set the switch or director offline through
the Set Online State dialog box. Display
this dialog box by selecting Set Online
State from the Element Manager
Maintenance menu.

Cannot have E-Ports if
Management Style is FICON unless
SANtegrity feature is installed.
Please contact your sales
representative.

Firmware is below the required level
and you attempted to change
management style from Open
Systems to FICON management style
with E_Ports configured, but
SANtegrity Binding is not installed.

Informational message. If firmware is
below the required level and you install
SANtegrity Binding before changing to
FICON management style, then E_Ports
will remain as E_Ports when you change to
FICON management style. If SANtegrity
Binding is not installed, setting a director
to FICON management style will change
all E_ports to G_Ports.

Cannot have spaces in field.

Spaces are not allowed as part of the
entry for this field.

Delete spaces from the field entry.

Cannot install firmware to a
director with a failed CTP card.

A firmware version cannot be
installed on a director with a failed
control processor (CTP) card.

Replace the failed CTP card and retry the
firmware installation.

Cannot install firmware to a switch
with a failed CTP card.

Firmware cannot be installed on a
switch with a defective CTP card.

Note that the CTP card is not a FRU. If it
fails, the switch must be replaced. After
replacement, retry the firmware install to
the switch.

Cannot modify director/switch
speed. Ports speeds cannot be
configured at a higher data rate
than the director/switch speed.

Port speeds cannot be configured at a
higher data rate than the director
speed. This message appears when
you set director sped to 1 GB/sec
through the Configure Switch
Parameters dialog box and at least
one of the ports is running at 2
Gb/sec.

Either return the director speed to 2
Gb/sec or configure all port data speeds
to 1 Gb/sec through the Configure Ports
dialog box.

Table 8

Element Manager messages (continued)

Message

Description

Action

This manual is related to the following products: