beautypg.com

GW Instek GSP-930 User Manual User Manual

Page 153

background image

ADVANCED OPERATION

151

Example

3

rd

Order Upper

Base Lower

3

rd

Order Lower

Limit

Base Upper

Δf

Operation:

1. Press

Meas

> TOI[F6]>TOI[F1] and turn TOI

on.

Any other measurement mode will automatically be
disabled.

2. The display splits into two screens. The top

shows the trace with markers in the upper and
lower base frequencies and the upper and
lower 3

rd

order intermodulation products. The

bottom screen shows the TOI measurements
and pass/fail results.

TOI measurement and results

3

rd

Order

lower

marker

Lower and

upper base

3

rd

Order

upper

marker