beautypg.com

GW Instek GSP-930 User Manual User Manual

Page 139

background image

ADVANCED OPERATION

137

For P<31, two additional power limits (shown below)
can be selected via the

Additional Max Out. Pwr

option for Home BS applications:

(The default value for Δfmax is 14.5 MHz. Δfmax can
be user-defined)

6≤P≤20

Unit: MHz

Abs

[1]

RBW

12.5 ≤E< Δfmax P- 56dB

1MHz

P<6

Unit: MHz

Abs

[1]

RBW

12.5 ≤E< Δfmax -50dBm

1MHz

3GPP-FDD BS
Additional
Requirements

For operation in bands II, IV, V, X, XII, XIII, XIV and
XXV, additional requirements (listed below) apply in
addition to the minimum requirements listed above.

Bands:
II, IV, X

Unit: MHz

Additional

[3]

RBW

2.5 ≤A<3.5

-15dBm

30kHz

3.5≤B< Δfmax -13dBm

1MHz

Bands: V

Unit: MHz

Additional

[3]

RBW

2.5 ≤A<3.5

-15dBm

30kHz

3.5≤B< Δfmax -13dBm

100kHz

Bands:
XII, XIII, XIV

Unit: MHz

Additional

[3]

RBW

2.5 ≤A<3.5

-13dBm

30kHz

3.5≤B< Δfmax -13dBm

100kHz

3GPP-FDD UE

The channel span is set to 5MHz.

Note: A, B, C, D, E denote offsets 1 to 5, respectively.

Unit: MHz

Rel

Abs

[1]

RBW

2.5 ≤A<3.5 -35~-50dBc

-71.1dBm

30kHz

3.5 ≤B<7.5 -35~-39dBc

-55.8dBm

1MHz

7.5 ≤C<8.5 -39~-49dBc

-55.8dBm

1MHz

8.5 ≤D<12.5 -49~-49dBc

-55.8dBm

1MHz