Sierra M6‐2 SAS/SATA Protocol Analyzer User Manual

Bus Condition

Double‐click Bus Condition in the Pattern window to open the Bus Conditions dialog.

Figure 2.44: SAS: Bus Conditions Dialog

SAS vs. SATA: SATA Dialog separates the COMINIT and COMRESET check boxes and
replaces COMWAKE with Host COMWAKE and COMSAS with Device COMWAKE.

Check Conditions on which to trigger, then click OK.

Note:

You can define triggering for specific ports by checking or unchecking Port IDs.

Symbol

Double‐click Symbol in the Pattern window to open the Symbol dialog.

Figure 2.45: Symbol Dialog

Choose a symbol type by checking either the K Symbol or D Symbol option, then click the
down arrow in the Symbol dropdown list, choose a symbol to trigger on, and click OK.
Note that the D Symbol choice does not have a down arrow.

To choose a D symbol, click the D symbol option button and enter a Hex value.

Port ID