Teledyne LeCroy Sierra M6-2 SAS_SATA Protocol Analyzer User Manual User Manual
Page 176

Teledyne LeCroy
Performance Analysis
174
Sierra M6‐2 SAS/SATA Protocol Analyzer User Manual
Figure 2.169: SATA: Settings Dialog
The settings dialog allows you to set the Analysis update interval and define the counter
mode.
1. Choose the Update Interval in the range of 1 ms to 245 minutes.
2. Set the Counter Mode to either Cumulative or Instantaneous.
Cumulative causes the measurement counters to continually increment>
Instantaneous causes the measurement counters to reset for each Update interval.
3. Set the Analyzer Speed for each port used.
4. To disable descrambling, check the Disable Descrambling check box.
5. Enter a value for Primitive Response Timeout.
6. Choose the Align Transmission Period by checking the corresponding option
button.
7. To select Protocol Errors to exclude from the analysis, click the Protocol Error Mask
button and check any or all of the protocol errors to exclude. See
8. To save the analysis result for later review, check Save to file and enter the path in
which to save the result.
9. To include a descriptive note about the project, click the Notes tab and enter
information in the Notes dialog. See
“Add a Project Note” on page 112
.