beautypg.com

2 select device – Teledyne LeCroy Sierra M6-2 SAS_SATA Protocol Analyzer User Manual User Manual

Page 27

background image

Sierra M6‐2 SAS/SATA Protocol Analyzer User Manual

25

Expandability

Teledyne LeCroy

Figure 1.9: Cascading Wrongly

5. Make a note of the last four digits of the MAC address of the unit designated as

Unit 1 and the last four digits of the other units, in order of connection.

Figure 1.10: Address Digits

IMPORTANT!

Power up all units before starting the software.

1.9.2

Select Device

After starting the software, click on Configuration and select All Connected Devices (see
the following screen capture).

Incorrect way to connect:
The black color pin of the
ribbon wire is connected
in a different way between
the 2 connectors.

Cascading works incorrectly
in this case, the boxes are
connected but no traces
are captured.

Black color pin
of ribbon wire