Writable buffer size field, Error injection tab – Teledyne LeCroy Sierra M6-2 SAS_SATA Protocol Analyzer User Manual User Manual
Page 181

Sierra M6‐2 SAS/SATA Protocol Analyzer User Manual
179
Target and Device Emulation
Teledyne LeCroy
Writable Buffer Size Field
The writable buffer size field is about 3.5 GB. The buffer is cyclical in that it behaves in a
Circular Writable manner in the Host Emulator. Writing 500MB at address 00000000 and
1GB starting at address 00100000 still stores the contents of address 00000000. If you
start writing 2GB at address 3G, the contents of address 00000000 are overwritten after
1G.
After writing data to the Device Emulator and disconnecting/reconnecting by clicking
Start/Stop the data still remains in the Device Emulator.
Error Injection Tab
Clicking the Error Injection tab opens the General Errors dialog (see
and
see
).
SAS: In addition to specifying general errors, you can also set errors for Identify,
Connection Management, and SAS Commands by clicking the corresponding icon in the
Errors window.
76
14, 9, 8, 3, 2 and 1
77
7
78
8, 5, 4, 3, 2 and 1
79
7, 5, 4, 3, 2 and 1
82
0
83
10, 1, 0
84
7, 6, 1, 0
86
10, 1, 0
87
7, 6, 1, 0
100‐103
All
106
12
117‐118
All
215‐216
All
255
All
TABLE 2.1:
Word