beautypg.com

Writable buffer size field, Error injection tab – Teledyne LeCroy Sierra M6-2 SAS_SATA Protocol Analyzer User Manual User Manual

Page 181

background image

    

Sierra M6‐2 SAS/SATA Protocol Analyzer User Manual

179

Target and Device Emulation

Teledyne LeCroy

Writable Buffer Size Field

The writable buffer size field is about 3.5 GB. The buffer is cyclical in that it behaves in a
Circular Writable manner in the Host Emulator. Writing 500MB at address 00000000 and
1GB starting at address 00100000 still stores the contents of address 00000000. If you
start writing 2GB at address 3G, the contents of address 00000000 are overwritten after
1G.

After writing data to the Device Emulator and disconnecting/reconnecting by clicking
Start/Stop the data still remains in the Device Emulator.

Error Injection Tab

Clicking the Error Injection tab opens the General Errors dialog (see

Figure 2.174 on

page 180

and

see

Figure 2.175 on page 180

).

SAS: In addition to specifying general errors, you can also set errors for Identify,
Connection Management, and SAS Commands by clicking the corresponding icon in the
Errors window.

76

14, 9, 8, 3, 2 and 1

77

7

78

8, 5, 4, 3, 2 and 1

79

7, 5, 4, 3, 2 and 1

82

0

83

10, 1, 0

84

7, 6, 1, 0

86

10, 1, 0

87

7, 6, 1, 0

100‐103

All

106

12

117‐118

All

215‐216

All

255

All

TABLE 2.1:

Word

Bit Numbers of Settable Bits