Teledyne LeCroy
Compliance Test (SATA)
334
Sierra M6‐2 SAS/SATA Protocol Analyzer User Manual
6. Select the Compliance Type as Host or Device.
7. Select the Device Type as ATA or ATAPI.
8. When testing SSD devices, select the SSD Drive checkbox, to ensure correct test
results.
9. To view failed test traces in the sample viewer, check the
Automatically load failed test traces into Sierra trace viewer check box.
10. To save the failed test traces only, check the Save only failed test traces check box.
11. Enter a path and file name for the Compliance Report file, or use the default file
name and path:
C:\Program Files\LeCroy\SATA Protocol Suite\User\Compliance_Device1.rtf
12. Enter a path and file name for the Saved Traces, or use the default folder:
C:\Program Files\LeCroy\SATA Protocol Suite\User\
13. After you select tests, click Start.
14. The test runs and, after a brief period, displays the result.
Figure 3.159: Compliance Test Result
15. To save the current compliance setup for later use, click the Save button to open the
Save As dialog. Assign a meaningful name to the setup and save it as a *.cst
compliance file.
16. To run a previously defined setup, click the Load button and choose a previously
defined setup to run.
Note:
When you are running Compliance Test, do not connect the analyzer to the Host if testing a
Device. Do not connect the analyzer to the Device if testing Host. Such improper connections
can impact compliance‐test result validity.