beautypg.com

19 performance analyzer, 20 target emulator or device emulator – Teledyne LeCroy Sierra M6-2 SAS_SATA Protocol Analyzer User Manual User Manual

Page 40

background image

Teledyne LeCroy

Performance Analyzer

38

 

Sierra M6‐2 SAS/SATA Protocol Analyzer User Manual

In Easy Mode, on the Capture tab, select to capture Everything or Pattern. For Pattern,
select a Pattern. You can exclude patterns and frames. You can use different patterns for
pre‐trigger and post‐trigger.

In Easy Mode, on the Trigger tab, select the trigger type. For Pattern, select the pattern.

In Easy Mode, on the Initiator Setting or Host Setting tab, select the port and speed.
Select to run the Pattern Generator or Initiator Emulator or Host Emulator.

In Easy Mode, on the Settings tab, select trigger position and memory use. Also change
the Analyzer settings if necessary. Specify addresses, stops, times, and sizes, if necessary.

Use Advanced Mode only after you become familiar with the hardware and software and
have special needs.

1.19 Performance

Analyzer

To do a Performance Analysis, select File > New > SAS Performance Analyzer for SAS or 
File > New
> SATA Performance Analyzer for SATA. Choose settings in the Performance
Analysis dialog. Click Run Hardware (see

“Performance Analysis” on page 171

.)

1.20

Target Emulator or Device Emulator

To use the software as a target or device emulator, first select File > New > SAS Target 
Emulator
or SATA Device Emulator for a new project or File > Open an existing Emulator
file: .std Target Emulator file or .sde Device Emulator file (see

“Target and Device

Emulation” on page 176

). You can also use Project Setup > Last Target Emulator or Last 

Device Emulator.

In the Pages tab, change settings for the supported pages if necessary.

In the Error Injection tab, select General periodic errors, Identify frames,
Connection Management open and close connection errors, SAS Commands and events
errors, ATA Commands errors, or SATA Signature content.

Use the User‐defined Commands tab only after you have become familiar with
operations.

In the Settings tab, select addresses, sizes, times, and ports, if necessary.

You can capture traffic when using an Analyzer project (but not a Target Emulator
project). With a Protocol Analyzer open, open a Target Emulator. After checking the
settings, click the Activate/Deactivate (Active) device button. or select Project Setup > 
Active Device.
If you change Target Emulator settings, Deactivate and then Activate 
Device
.

1.21

Teledyne LeCroy SAS/SATA Protocol Suite Menu Options and
Toolbars

This section lists all the SAS/SATA Protocol Suite application menu options and the
toolbars.