3 pop-up menu, 4 file tabs, 5 error log – Teledyne LeCroy Sierra M6-2 SAS_SATA Protocol Analyzer User Manual User Manual
Page 417: 6 tooltips

Sierra M6‐2 SAS/SATA Protocol Analyzer User Manual
415
Starting the Script Editor
Teledyne LeCroy
5.9.3
Pop-up Menu
Right‐click anywhere in the script window to open a pop‐up menu with the following
options
.
Zoom In: Increases the size of the displayed elements
Zoom Out: Decreases the size of the displayed elements
Toolbars: Allows you select the toolbars to display on the top screen.
Status Bar: Toggles between hiding and displaying the status bar showing the
port status at the bottom of the screen.
Wrap: Wraps displayed packets within the window.
Compact: Displays each row on one line only, with no wrapping
5.9.4
File Tabs
At the bottom of the window is a tab that shows the name of the .ssg file. If your .ssg file
has an Include statement in it, the supporting Include files automatically open when the
.ssg file is first opened. Tabs for the opened Include files appear at the bottom of this
window.
Figure 5.14: File Tab
5.9.5
Error Log
Whenever you create a scripting error, a log opens at the bottom of the application
window. When the error is corrected, the window automatically closes.
Figure 5.15: Log
5.9.6
Tooltips
The Script Editor window includes extensive tooltips for each keyword. To see a tooltip,
hold the mouse pointer over a keyword.