beautypg.com

9 waveform display – Teledyne LeCroy Sierra M6-2 SAS_SATA Protocol Analyzer User Manual User Manual

Page 227

background image

    

Sierra M6‐2 SAS/SATA Protocol Analyzer User Manual

225

Analysis

Teledyne LeCroy

3.3.9

Waveform Display

You can enable a waveform display for all active ports, and perform timing
measurements, by positioning timing cursors within the waveform display (see

Figure 3.20 on page 225

).

Select View > Wave Form View or click the

 Show/Hide Waveform button on the

View Type toolbar to enable the waveform display.

The Compact View shows the OOB Sequence with speed negotiation.

Figure 3.20: SAS: Waveform View

Figure 3.21: SATA: Waveform View

Making a Timing Measurement

Timing measurements are made with two timing cursors T1 and T2. Click the left mouse
button in the gray bar on the top of the waveform display at a point for the T1 cursor, and
the right mouse button at a point for the T2 cursor. The time difference between the
cursors is on a line connecting the two cursors.

Figure 3.22: SATA: Timing Cursors Enabled