ATA Commands Errors (SATA only)
Click the ATA Commands icon in the Errors window to display the ATA Commands Error
Setting dialog.
Figure 2.187: SATA: Commands Error Setting Dialog
To set errors for ATA commands:
1. Click a command for which to set an error and then check the Generate Error when
check box and chose LBA or Command number with a value in the corresponding
text box.
Note:
Hard‐drive password security commands (as described in ATA8) are Data Set Management,
Write Uncorrectable Ext, Security Disable Password, Security Erase Password, Security Erase
Unit, Security Freeze Lock, Security Set Password and Security Unlock.
2. When you choose Command Number, you can use Repeat error for periodic series
of errors in commands. Set the number of times to repeat the error, by entering a
value in the Number of Error Commands text box.
Note:
Once you check the Generate Error when: check box for a command, a red status indication
appears next to the command selected indicating an error condition.
3. To force the system to send a defined response frame to the host, check the
Command fail on Response check box and then choose a pre‐defined response.
4. Repeat for every command for which to set an error.
Status
Indication