Modbus – IAI America ROBO Cylinder Series User Manual
Page 123

5. Modbus RTU
115
Modbus
5.4 Operation Commands and Data Rewrite (Query Using Code 05)
5.4.1 Writing to Coil
(1) Function
Change (write) the status of DO (Discrete Output) of a slave to either ON or OFF.
In case of broadcast transmission, the coils at the specified address of all slaves are rewritten.
(2) Start address list
Start address [H]
Symbol
Function
0401
SFTY
Safety speed command
0403
SON
Servo ON command
0407
ALRS
Alarm reset command
0408
BKRL
Brake forced-release command
040A
STP
Pause command
040B
HOME
Home return command
040C
CSTR
Positioning start command
0411
JISL
Jog/inch switching
0414
MOD
Teaching mode command
0415
TEAC
Position data load command
0416
JOG+
Jog+ command
0417
JOG-
Jog- command
0418
ST7
Start position 7 (solenoid valve mode)
0419
ST6
Start position 6 (solenoid valve mode)
041A
ST5
Start position 5 (solenoid valve mode)
041B
ST4
Start position 4 (solenoid valve mode)
041C
ST3
Start position 3 (solenoid valve mode)
041D
ST2
Start position 2 (solenoid valve mode)
041E
ST1
Start position 1 (solenoid valve mode)
041F
ST0
Start position 0 (solenoid valve mode)
0426
CLBR
Load cell calibration command
0427
PMSL
PIO/Modbus switching specification
042C
STOP
Deceleration stop