5. Modbus RTU
113
Modbus
5.3.23 Force Feedback Data Read <
(1) Function
The monitored data of load cell measurement (push force) is read.
The unit is 0.01 N.
(2) Query format
Field
Number of data items
(number of bytes)
RTU mode
8-bit data
Remarks
Start
None
Silent interval
Slave address [H]
1
Arbitrary
Axis number + 1 (01
H
to 10
H
)
Function code [H]
1
03
Register reading
Start address [H]
2
901E
Force feedback monitor
Number of registers [H]
2
0002
Reading address
901F
H
~901F
H
Error check [H]
2
CRC (16 bits)
End
None
Silent interval
Total number of bytes
8
(3) Response format
A response message contains 16 bits of data per register.
Field
Number of data items
(number of bytes)
RTU mode
8-bit data
Remarks
Start
None
Silent interval
Slave address [H]
1
Arbitrary
Axis number + 1 (01
H
to 10
H
)
Function code [H]
1
03
Register reading
Number of data bytes [H]
1
04
Reading 2 register = 4 bytes
Data [H]
4
Load cell
measurement
Current push force [N]
Unit: 0.01 N
Error check [H]
2
CRC (16 bits)
End
None
Silent interval
Total number of bytes
9