beautypg.com

Installation environment – IAI America ASEL User Manual

Page 44

background image

Chapter 3 Installation and W

iring

Part 1 Installation

22

Part 1 Installation

As for the use environment, this product can be used in an environment of pollution degree 2

*1

or

equivalent.

*1 Pollution degree 2: Normally only non-conductive pollutants exist, which are expected to be

temporarily conductive due to condensation. (EN60947-5-1)

2. Installation Environment

(1) When installing and wiring the controller, do not block the ventilation holes provided for cooling.

(Insufficient ventilation will not only prevent the product from functioning fully, but it may also result in

failure.)

(2) Prevent foreign matter from entering the controller through the ventilation holes. Since the controller is

not designed as dustproof or waterproof (oilproof), avoid using it in a dusty place or place subject to

oil mist or splashed cutting fluid.

(3) Do not expose the controller to direct sunlight or radiant heat from a high heat source such as a heat-

treating furnace.

(4) Use the controller in a non-condensing environment free from corrosive or inflammable gases.

(5) Use the controller in an environment where it will not receive external vibration or impact.

(6) Prevent electrical noise from entering the controller or its cables.

Environmental Condition of Controller

Item

Specification and description

Operating temperature range 0 ~ 40qC

Operating humidity range

10% ~ 95% (Non-condensing; conforming to JIS C3502 RH-2)

Storage temperature range -25qC ~ 70qC (Excluding the battery)

Maximum operating altitude 2000 m

Protection class

IP20

Vibration

10 d f < 57: 0.035 mm (continuous), 0.075 mm (intermittent)

57 d f d 150: 4.9 m/s

2

(continuous), 9.8 m/s

2

(intermittent)

X, Y and Z directions

Impact

147 mm/s

2

, 11 ms, half-sine pulse, 3 times each in X, Y and Z

directions