Appendix

List of Parameters

395

Appendix

Other Parameters

No.

Parameter name

Default value

(Reference)

Input range

Unit

Remarks

12 Automatic operation

recognition type

0

0 ~ 3

0: Program is running AND all-operation-cancellation factor

is not present

1: [Program is running OR in AUTO mode] AND all-

operation-cancellation factor is not present

13 ~

19

(For expansion)

0

20 System-memory backup

battery installation

function type

0

0 ~ 2

0: Not installed (SEL global data/error lists cannot be

recovered from the flash ROM)

1: Not installed (SEL global data/error lists can be

recovered from the flash ROM)

2: Installed

* When the power is turned on without battery installed,

point data can be copied from the flash ROM. * Use of

setting “1” will be prohibited for the time being due to

limitations. * When point data is lost due to a battery

error, the point data valid before the flash ROM was

written can be restored o Input “0” (not installed) and

transfer the setting to the controller, and then perform

a software reset without writing the flash ROM. The

point data last written to the flash ROM will be

restored. Thereafter, reset this parameter to the

original value. (No remedy is available for recovery of

SEL global data/error lists.)

21 Manual mode type

0

0 ~ 5

0: Always enable edit and SIO/PIO start (Initial condition

after connection = With safety speed)

1: Select edit and start (with password) (EU, etc.)

2: Always enable edit and SIO/PIO start (Initial condition

after connection = Without safety speed (cancellation))

* Referenced by the PC/TP.

22 Control use region

0

0 ~ 99

0: J, 1: E, 2: EU

23 PSIZ command function

type

0

0 ~ 5

0: Maximum number of point data areas

1: Number of point data used

24 Local variable number

for storing SEL

communication

command return code

99

1 ~ 99

1001 ~ 1099

25 Operation mode type

0

0 ~ 16

0: Program mode

1 to 16: Positioner mode

26 ~

29

(For expansion)

0

30 Option Password 00

0H

0H ~

FFFFFFFFH

HOME command option (Change prohibited)

* Change is prohibited unless instructed by the

manufacturer.

31 Option Password 01

0H

0H ~

FFFFFFFFH

Reserved (Change prohibited)

* Change is prohibited unless instructed by the

manufacturer.

32 Option Password 02

0H

0H ~

FFFFFFFFH

Reserved (Change prohibited)

* Change is prohibited unless instructed by the

manufacturer.

33 ~

35

(For expansion)

0

0H ~

FFFFFFFFH