IAI America ASEL User Manual
Page 185

Part 2 Programs
Chapter 3 Explanation of Commands
163
Part 2 Programs
z
MOVP (Move PTP by specifying position data)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1
Operand 2
Output
(Output, flag)
Optional
Optional
MOVP
Position
number
Prohibited
PE
[Function] Move the actuator to the position corresponding to the position number specified in operand
1, without interpolation (PTP stands for “Point-to-Point”).
The output will turn OFF at the start of axis movement, and turn ON when the movement is
complete.
[Example 1]
VEL
100
Set the speed to 100 mm/s.
MOVP 1
Move the axes to the position corresponding to position No.
1 (200, 100).
[Example 2]
VEL
100
Set the speed to 100 mm/s.
LET
1
2
Assign 2 to variable 1.
MOVP *1
Move the axes to the position corresponding to the content
of variable 1 (position No. 2, or (100, 100)).
Position data display in PC software
No.
Axis 1 (X-axis) Axis 2 (Y-axis)
Vel
Acc
Dcl
1
200.000
100.000
2
100.000
100.000
(Note) If no position data is available and acceleration and deceleration are not specified by an ACC
(DCL) command, each axis will move according to all-axis parameter No. 11, “Default
acceleration” and all-axis parameter No. 12, “Default deceleration.”
Travel path from the home to the position corresponding to position No. 1 (200, 100)
X-axis
Y-axis
Only the Y-axis completes
movement.
Each axis moves at 100 mm/s.
Home 0
100 mm
100 mm
200 mm