Part 3 Positioner Mode
Chapter 6 DS-S-C Compatible Mode
338
Part 3 Positioner Mode
Chapter 6 DS-S-C1 Compatible Mode
In this mode, the same I/O assignments used by the conventional controller model DS-S-C1 are used.
As added functions, the cancellation (CANC) input, interpolation setting input, system battery error output,
and absolute battery error output are available, and the number of positions has been increased.
1. I/O Interface List
Pin
No. Category
Port
No.
Signal name
Signal
symbol
Function overview
Cable
color
1A
P24
External power supply 24 V
P24
1-Brown
1B
016 Position No. 1000 input
PC1000
(Same as PC1 through 800)
1-Red
2A
017
-
1-Orange
2B
018
-
1-Yellow
3A
019
-
1-Green
3B
020
-
1-Blue
4A
021
-
1-Purple
4B
022
-
1-Gray
5A
023 CPU reset
CPRES
The CPU will be restarted at the leading edge of this signal.
1-White
5B
000 Start
CSTR
The actuator will start moving at the leading edge of this
signal.
1-Black
6A
001 Pause
STP
The actuator can be moved when this signal is ON, and will
decelerate to a stop when the signal turns OFF.
2-Brown
6B
002 Cancellation
CANC
The remaining travel distance will be cancelled if this signal
turns ON.
2-Red
7A
003 Interpolation setting
LINE
With the 2-axis specification, linear interpolation operation
will start when the start input signal is turned ON while this
signal is ON.
2-Orange
7B
004 Position No. 1 input
PC1
2-Yellow
8A
005 Position No. 2 input
PC2
2-Green
8B
006 Position No. 4 input
PC4
2-Blue
9A
007 Position No. 8 input
PC8
2-Purple
9B
008 Position No. 10 input
PC10
2-Gray
10A
009 Position No. 20 input
PC20
2-White
10B
010 Position No. 40 input
PC40
2-Black
11A
011 Position No. 80 input
PC80
3-Brown
11B
012 Position No. 100 input
PC100
3-Red
12A
013 Position No. 200 input
PC200
3-Orange
12B
014 Position No. 400 input
PC400
3-Yellow
13A
Input
015 *Position No. 800 input
PC800
Input the position number corresponding to the position you
want to move the actuator to.
Be sure to specify a position input by no later than 6 msec
before the start input signal turns ON.
Position numbers are input as BCD codes. (PC1 through 8
indicate the one’s place, PC10 through 80 indicate the ten’s
place, PC100 through 800 indicate the hundred’s place, and
PC1000 indicates the thousand’s place.)
3-Green
13B
300 *Alarm
ALM
This signal remains ON if the controller is normal. It will turn
OFF if an alarm occurs.
3-Blue
14A
301 Ready
RDY
This signal will turn ON when the controller becomes ready. 3-Purple
14B
302 Positioning complete
PEND
This signal will turn ON once the actuator has moved to the
target position and entered the positioning band.
3-Gray
15A
303
-
3-White
15B
304
-
3-Black
16A
305
-
4-Brown
16B
306 System battery error
SSER
This signal will turn ON when the voltage of the system-
memory backup battery drops to the voltage-low warning
level.
4-Red
17A
Output
307 Absolute battery error
ABER
This signal will turn ON when the voltage of absolute-data
backup battery drops to the voltage-low warning level.
4-Orange
17B
N
External power supply 0 V
N
4-Yellow
Caution: The power wiring polarities are reversed from those of the PNP specification applicable to the
old DS-S-C1 controller. As shown above, pin Nos. 1A and 17B are connected to 24 V and 0 V,
respectively, even in the PNP specification.