13 Max Error
There was an attempt to exceed the maximum value
allowed for a parameter value.
14 Invalid Command PLC
An invalid command was encountered during
compilation of the PLC program.
15 Invalid Operand PLC
An invalid operand was encountered during
compilation of the PLC program.
16 No
No END command was found during compilation of
the PLC program.
17 PLC Memory Limit
The internal memory limit for the PLC program was
reached while compiling the PLC program. The PLC
program should be reduced in size.
18 Defaults Loaded
The default parameter values have been loaded into the
Control Parameters.
19 Backup Loaded
The backup parameter values have been loaded into
the Control Parameters.
20 Backup Saved
The Control Parameter values have been saved to
backup storage.
21 Checksum Error
A checksum calculation error has occurred as a result
of the last request.
22 Faults Cleared
The fault counters have been cleared.
23 Passed
The requested memory test passed.
24 Failed
The requested memory test failed.
25 No Compare Parm
No compare parameter.
26 Divide by Zero
The last request caused a “divide by zero” in an
internal calculation.
27 Long Word Overflow
The last request caused a “long word overflow” in an
internal calculation.
28 Parm Transfer Limit Error An attempt was made to exceed the maximum number
of parameters allowed for a request.