Appendix C: Parameter Summary Numeric Quick Reference (continued)
MP-126 PLC 147-140
PLC 147-140 (MP-126) displays the status of the internal PLC control bits 147-140 (See graphic below). A “1” in any bit
indicates that the bit is “active”. Blk Sel A, B, C select the block that is active, if Blk Sel Source (CP-378) has been set
to “1” (DgIn). The chart below indicates which block has been selected, based on the Block Select A, B or C inputs.
Block Select A
Block Select B
Block Select C
Not In Use
Not In Use
Not In Use
Not In Use
Not In Use
Blk Sel
C B A
Block Selected
0 0 0
0
0 0 1
1
0 1 0
2
0 1 1
3
1 0 0
4
1 0 1
5
1 1 0
6
1 1 1
7
Bit Name
Description
Blk Sel A
Block Select A
Blk Sel B
Block Select B
Blk Sel C
Block Select C
Not In Use
Not In Use
Not In Use
Not In Use
Not In Use
Minimum Value: 00000000
Maximum Value: 11111111
Units: Coded