CONTREX CX-1200 User Manual
Page 421

C - 75
(Continued)
Appendix C: Parameter Summary Numeric Quick Reference (continued)
CP-472 Frame Format
Frame Format (CP-472) determines the parity, the number of data bits, and the number of stop bits for the serial
communications.
1 = N,8,1 = No Parity, 8 data bits, 1 stop bit (10 bit frame - ASCII or Binary) (default)
2 = E,7,1 = Even Parity, 7 data bits, 1 stop bit (10 bit frame-ASCII only)
Minimum Value: 1
Maximum Value: 2
Default Value: 1
Units: Coded
CP-473 SerCom Char Out
When a new value is entered in SerCom Char Out (CP-473), it is transmitted out the RS-485 serial port at the Baud Rate
(CP-471) and the Frame Format (CP-472). SerCom Char Out (CP-473) is a decimal number.
Minimum Value: 0
Maximum Value: 255
Default Value: 0
Units: Decimal Character
CP-474 Video Mode
Video Mode (CP-474) determines how the LCD Screen Display will be displayed, per the list below:
3 = Standard Video w/Border
2 = Reverse Video
1 = Standard Video(default)
Minimum Value: 1
Maximum Value: 3
Default Value: 1
Units: Coded
CP-475 Contrast Value
Contrast Value (CP-475) determines the contrast for the LCD Screen Display. The higher values darken the pixels and
lower values lighten the pixels.
Minimum Value: 8
Maximum Value: 32
Default Value: 18
Units: Contrast Integer