Cx-1200 appendix h, Appendix h: error code definitions – CONTREX CX-1200 User Manual
Page 469
H - 1
Error
Definition
(Continued)
Acl Tm High
Acceleration time is too high.
Acl too Hi
Acceleration rate is too high.
Adrs Error
Address Error, there is an internal address conflict with the CPU.
Bad Blk Calc
During calculations for one of the parameter blocks, an error was
encountered causing the block to be marked as bad. The block
parameter value(s) in error should be corrected.
Bad Blk Sel
An attempt was made to switch to a bad parameter block.
Binary Only
The number is Binary, only “1’s” and “0’s” may be entered.
BkUp Loaded
Prompt which displays on completion of loading a code parameter
backup into main CP list.
Blk Parm Err
An error was encountered in the block parameters.
Blk Val Err
An error was encountered in the block values of a block.
Buss Error
There is an internal buss conflict with the CPU.
ChkSm Error
Checksum Error, the checksum calculated for memory data is not
correct.
Dcl Tm High
Deceleration time is too high.
Default Set
Prompt after resetting a parameter back to its default value.
Defaults Set
Prompt after resetting all parameters back to their default values.
Divide By 0
Math error has occurred internal resulting in divide by zero.
DP Present
Decimal point already present in the number you are entering.
Dspl Error
Display Error, an error has occurred when attempting to display a
parameter (e.g., the parameter does not exist).
Field Full
The maximum number of characters (digits, decimal point, negative
sign) allowed for parameter entry has been reached while entering a
number via the keypad. You tried to enter more numbers/characters
than will fit into the space allotted for the parameter value entry.
Flts Cleared
Prompt to indicate that the faults have been cleared, as a result of
entering a 1 into Clr Fault Cntrs (CP-491)
Gen Intrpt
Some error occurred during the controls program execution to cause
a General Interrupt.
APPENDIX H: ERROR CODE DEFINITIONS