CONTREX CX-1200 User Manual
Page 414

C - 68
(Continued)
Appendix C: Parameter Summary Numeric Quick Reference (continued)
CP-438 DN MAC ID
DN MAC ID is the DeviceNet Media Access Control Identifier. The MAC ID is used to assign a uniqe identifier or
address to each node on the network. Assign a different MAC ID to each CX-1200 device on the network from 0 to 63.
Minimum Value: 0
Maximum Value: 63
Default Value: 63
Units: ID
CP-439 DN Baud Rate
The DN Baud Rate is the network data or transfer rate. Enter the number from the listing below that corresponds to the
desired baud rate:
1 = 125k bps
2 = 250k bps
3 = 500k bps
Minimum Value: 1
Maximum Value: 3
Default Value: 1
Units: Coded
CP-440 Lg Number Parm
Use Large Number Parameter (CP-440) to select the parameter that displays in the large number display in the Status
screen (refer to the status screen in Operation: Screen Operation). You can also use the Code key to access and
change CP-440 in the Status screen.
Minimum Value: 1
Maximum Value: 479 (restricted)
Default Value: 40
Units: Parameter Code
CP-441 Status Line 1
Use Status Line 1 (CP-441) to select the parameter that displays on the first line (under the Large Number Display) of the
Status screen (refer to the status screen in Operation: Screen Operation). You can also use the Code key to access
and change CP-441 in the Status screen.
Minimum Value: 1
Maximum Value: 667
Default Value: 201
Units: Parameter Code
CP-442 Status Line 2
Use Status Line 2 (CP-442) to select the parameter that displays on the second line (under the Large Number Display) of
the Status screen (refer to the status screen in Operation: Screen Operation). If you want this line to remain blank,
enter a “0” in CP-442. You can also use the Code key to access and change CP-442 in the Status screen.
Minimum Value: 0
Maximum Value: 667
Default Value: 50
Units: Parameter Code
CP-443 Status Line 3
Use Status Line 3 (CP-443) to select the parameter that displays on the third line (under the Large Number Display) of
the Status screen (refer to the status screen in Operation: Screen Operation). If you want this line to remain blank,
enter a “0” in CP-443. You can also use the Code key to access and change CP-443 in the Status screen.
Minimum Value: 0
Maximum Value: 667
Default Value: 7