H - 3
Appendix H: Error Code Definitions (continued)
(Continued)
Error
Definition
Minus First
When entering the value for this parameter the minus sign (-) must
be entered first.
No
During compilation of the PLC program, no END command was
found.
No Cmpr Parm
Invalid comparison parameter entered.
Not Allowed
The last action attempted is not allowed.
Not Processd
The request for a parameter value change was not processed due to a
“combo” check error that occurred as a result of some calculation
for a related parameter value or a parameter in a block of
parameters. May be the result of a block parameter transfer to the
control via serial communications.
Not Ready
The control was “not ready” to process the last request.
NVRAM Failed
The memory test for the nonvolatile RAM has failed.
NVRAM Passed The memory test for the nonvolatile RAM has passed.
Only 1 Page
Occurs when the page up or page down key is pressed and there is
only one page to display.
Parm Mem Lmt
Indicates that the internal memory limit for parameters in block
parameters has been exceeded, and therefore the number of
parameters defined in block parameters must be reduced.
PLC BkUp set
Prompt to indicate that the PLC program has been changed to be the
same as the backup PLC program that was saved to backup.
PLC Dflt set
Prompt to indicate that the PLC program has been changed to be the
same as the default PLC program.
PLC Mem Lmt
During compilation of the PLC program, the internal memory limit
set for the PLC program has been exceeded. The PLC program
should be reduced.
Power Loss
Indicates that a momentary loss of AC power was detected.
Ratio too Hi
The ratio is too high.