Cx-1200 appendix c – CONTREX CX-1200 User Manual
Page 347
![background image](/manuals/334431/347/background.png)
C - 1
(Continued)
Appendix C: Parameter Summary Numeric Quick Reference (continued)
APPENDIX C: PARAMETER SUMMARY NUMERIC
QUICK REFERENCE
MP-01 FI1 Hz
Frequency Input 1 Hertz (MP-01) displays the current frequency of the Frequency Input 1, in Hertz.
Minimum Value: -180000
Maximum Value: 180000
Units: Hertz
MP-02 FI1 RPM
Frequency Input 1 RPM (MP-02) displays the current speed of the Frequency Input 1 encoder in RPM, based on PPR
FI1 (CP-261).
Minimum Value: -99999.9
Maximum Value: 99999.9
Units: RPM
MP-03 FI2 Hz
Frequency Input 2 Hz (MP-03) displays the current frequency of the Frequency Input 2, in Hertz.
Minimum Value: -180000
Maximum Value: 180000
Units: Hertz
MP-04 FI2 RPM
Frequency Input 2 RPM (MP-04) displays the current speed of the Frequency Input 2 encoder in RPM, based on PPR
FI2 (CP-266).
Minimum Value: -99999.9
Maximum Value: 99999.9
Units: RPM
MP-05 Ld EU/Tm
Frequency Input 1 Engineering Units per Time (MP-05) displays the current speed of the Frequency Input 1 in the
Engineering Units per Time (EU/Tm) relative to the Pulses FI1 (CP-262), EU FI1 (CP-263) and Time Base (CP-209). The
placement of the decimal point is the same as the placement of the decimal point in EU FI1 (CP-263).
Minimum Value: -9999999
Maximum Value: 9999999
Units: EU/Tm
MP-06 Fb EU/Tm
Frequency Input 2 Engineering Units per Time (MP-06) displays the current speed of the Frequency Input 2 in the
Engineering Units per Time (EU/Tm) relative to the Pulses FI2 (CP-267), EU FI2 (CP-268) and Time Base (CP-209). The
placement of the decimal point is the same as the placement of the decimal point in EU FI2 (CP-268).
Minimum Value: -9999999
Maximum Value: 9999999
Units: Counts