Appendix C: Parameter Summary Numeric Quick Reference (continued)
2 = Current
1 = Voltage (default)
Minimum Value: 1
Maximum Value: 2
Default Value: 1
Units: Coded
CP-292 AO RA
Analog Output Reference A (CP-292) scales the Auxiliary Board Analog Output from the units of the selected parameter
to the units of the output, generally measured in volts or milliamps.
Minimum Value: -15.0
Maximum Value: 20
Default Value: -10.0
Units: Volts or Milliamps
CP-293 Val@AO RA
Value @ Analog Output Reference A (CP-293) scales the Auxiliary Board Analog Output from the units of the selected
parameter to the units of the output; generally measured in volts or milliamps. Enter the parameter value that
corresponds to AO RA (CP-292).
Minimum Value: -9999999
Maximum Value: 9999999
Default Value: -2000
Units: Parameter Value
CP-294 AO RB
Analog Output Reference B (CP-294) scales the Auxiliary Board Analog Output from the units of the selected parameter
to the units of the output; generally measured in volts or milliamps. Enter the parameter value that corresponds to
VAL@AO RB (CP-295).
Minimum Value: -15.0
Maximum Value: 20
Default Value: 10.0
Units: Volts or Milliamps
CP-295 Val@AO RB
Value at Analog Output Reference B (CP-295) scales the Auxiliary Board Analog Output from the units of the selected
parameter to the units of the output, (generally measured in volts or milliampere). Enter the parameter value that
corresponds to AO RB (CP-294).
Minimum Value: -9999999
Maximum Value: 9999999
Default Value: 2000
Units: Parameter Value
CP-300 Ref Ramps
The acceleration rate for the application selected are determined by the Acl Tm RUN (CP-301) and the Ref Ramps (CP-
300). The deceleration rate (from a faster speed to a slower speed) for the application selected, are determined by the Dcl
Tm RUN (CP-303) and the Ref Ramps (CP-300).
Minimum Value: 0.001
Maximum Value: 9999999
Default Value: 100
Units: EU/Tm