Appendix C: Parameter Summary Numeric Quick Reference (continued)
CP-451 Diag DO Shift
When in Diagnostics State, Diagnostics Digital Out Shift (CP-451) may be used to activate the digital outputs one at a
time.
Warning: The actuator may energize if you change Diag DO (CP-452). Stand clear of the system.
8 = Zero Speed
Activated
7 = Hi/Low Spd Alm
Activated
6 = Foll Sync Absent
Activated
5 = Lead Sync Absent Activated
4 = Fwd/Rvs
Activated
3 = Sync Alarm
Activated
2 = Batch Done
Activated
1 = Drive Enable
Activated
0 = Off (default)
Minimum Value: 0
Maximum Value: 8
Default Value: 0
Units: Coded
CP-452 Diag DO
Diagnostic Digital Out (CP-452) controls the digital outputs when Diagnostics En (CP-450) is set to “1” (On or enabled)
during diagnostics. It is an 8 Bit Binary number with 1 bit per output. If the bit is a “1”, then the corresponding
output is pulled “low”. When you enter diagnostics, Diag DO (CP-452) is forced equal to the current DO 7..0 (MP-102)
so that there is no unexpected change in the outputs. Change the outputs through Diag DO (CP-452) while performing
the diagnostics.
Warning: The actuator may energize if you change Diag DO (CP-452). Stand clear of the system.
DO-0/Drive Enable
DO-1/Batch Done
DO-2/Sync Alarm
DO-3/Fwd/Rvs
DO-4/Lead Sync Absent
DO-5/Foll Sync Absent
DO-6/Hi/Low Speed Alarm
D-7/Zero Speed
Minimum Value: 00000000
Maximum Value: 11111111
Default Value: 00000000
Units: Coded