7 - 51
Response Data Field Definitions:
Byte #
Type
Description
5
byte
Error code result from Setting Trace Parameter 1
6-7
UINT
Trace Parameter 1 value
8
byte
Error code result from Setting Trace Parameter 2
9-10
UINT
Trace Parameter 2 value
11
byte
Error code result from Setting Trace Parameter 3
12-13
UINT
Trace Parameter 3 value
14
byte
Error code result from Setting Trace Parameter 4
15-16
UINT
Trace Parameter 4 value
17
byte
Error code result from Setting Pre-Trigger Time
18-19
UINT
Pre-Trigger Time value setting (seconds)
20
byte
Pre-Trigger Time value resolution byte