Cx-1200 appendix i – CONTREX CX-1200 User Manual
Page 474

I-1
APPENDIX I: SERIAL COMMUNICATIONS ERROR
CODE DEFINITIONS
# Name
Definition
0 OK
Request processed
1 General Data Error
A non-specified error occurred as a result of the last
serial communications transmission. Check the
contents of the last message transmission against
the protocol definition.
2 Res Error
The resolution for the Control Parameter value
exceeds the minimum or maximum that is allowed.
3 Invalid Parm
The requested parameter does not exist.
4 String too long
The custom engineering units string that was sent
exceeds the 15 character limit and was truncated to
15 characters.
5 Out of Range
The parameter requested is above or below the
available number of parameters, or the address
requested for a memory read is not within the
memory address range.
6 Not Allowed
The request is not allowed.
7 Lockout During RUN
An attempt was made to change a parameter value
for a parameter that is locked out during run, while
the control is in run (state).
8 Not Ready
The CX-1200 was “not ready” to receive the last
request.
9 Block Parm Error
An error was encountered while processing a block
parameter request.
10 Block Value Error
An error was encountered while processing a block
value request.
11 Parm Memory Limit
The internal memory limit for block parameters was
exceeded during processing of a block parameter
change.
12 MIN Error
There was an attempt to exceed the minimum value
allowed for a parameter value.
(Continued)