CONTREX CX-1200 User Manual
Page 278
![background image](/manuals/334431/278/background.png)
7 - 39
FUNCTION (03) DATA READ PARAMETER BLOCK
Table 43 Host Transmission
Byte #
DESC
Decimal
2
9-39
1-99
3
1-999
3
0-65535
1
2
3
4
5
6
7
8
9
STX
Length
Address Function
Parm Number
ETX
CRC
Hex
02
09-27
01-63
03
0001-03E7
03
0000-FFFF
Data Field per Table 43
Number of parameters x 2 bytes/parameter (16 parameters max. = 32 bytes)
Parameter Number - WORD (2 bytes) for each parameter request
Message Length = 9 to 39 bytes
Table 44 CX-1200 Response
Byte #
DESC
Decimal
1
2
3
4
5-13
14
15
16
STX
Length
Address Msg Error Data Field
ETX
CRC
Hex
2
16-151
1-99
0-255
3
0-65535
02
10-97
01-63
00-FF
03
0000-FFFF
Data Field per Table 44
Number of parameters x 9 bytes/parameter (16 parameters max. = 144 bytes)
Byte #
DESC
Decimal
5
6
7
8
9
10
11
12
13
Error Parmameter Number Control
Res
Parameter Value
Code
Byte
Hex
0-32
1-999
0-244
0-9
-2147483648-2147483647
00-20
0000-03E7
00-F4
00-09
80000000-7FFFFFFF
Parameter Error Code
- 1 byte
Parameter Number
- WORD (2 bytes)
Parameter Control byte - 1 byte
Resolution
- 1 byte
Parameter Value
- LONG (4 bytes)
Message Length = 16 to 151 bytes